If you must change the health center in the home can have unpleasant surprises, or the installer will warn you as many parts that do not even think he was buying or even worse, but everything is new , starts the water works is not correct, water is not clean, or worse, wake up flooded.
We'll tell you what to expect and how not having this problem. Depending on the water (hot, cold, housekeeper, rainwater), pipes and other system components are selected and assembled differently.
Tube material can be in cold water installations inside the steel pipes, galvanized steel pipe, copper pipes, brass tubes, plastic tubes, glass tubes are used. Drinking water is not black steel pipe. Water pipes should be fairly short, and follow the direct route to points of consumption: complete systems of pipe used, including hooks, safety and equipment, maintenance and repair.
Installation pipes must be designed to ensure stability and building the system easily accessible for maintenance and repairs, and any defects or damage to the integrity of the building.
Water lines installed: in areas where frost buried down in / on the envelope that protects the building in terms of heating technology, in a concrete foundation in the ground beneath the floor level. These tubes do not separate the walls from the spa room or lounge, if you weigh less than 22 kg/m2 or in / on the roof.
The water lines are installed with flow in the opposite direction.
Necessarily pipes should be insulated. The minimum thickness of insulation depends on where they are installed. If it's taking a risk of corrosion of water protection measures (physical therapy, magnetic field by water or chemicals).
Each tube should have a single branch of the public. The slope is the connection of pipes min. 0.3% for pipelines. Soil depth of 1.2 to 1.6 m, max. 2 m. The area of ââprotection against damage caused by the loss of 2 m caused on both sides of the pipe, measure the tube axis.
individual buildings or automatic stations - - In buildings with the system of high-rise when the water comes from various sources (wells) are used for pumping in a well equipped with Jacuzzi Micro. In some cases, if consumers use to the public and other sources of water supply, there is a danger that both types of connection systems and the establishment of wells (with impurities), the public . To avoid this, use the check valve.
If the pressure of the water supply is less than the minimum pressure for operation of vulnerable consumers is necessary, it is necessary to use solutions with high water pressure. increased pressure pumps, tanks or altitude of the pumping station: This growth can be obtained by pressure.
The best system is chosen based on several factors: the maximum flow, usually in liters per second, the minimum quantity of water that can be obtained at the peak consumption, frequency and duration of consumption, the pressure required. Remember not to consider how and capital costs and operating the building and the importance of ensuring a steady supply of water, without interruption.
For system protection and reflux (reflux) to install, after entering the water pipe in the house, a fine filter - protects the valves and batteries
premature destruction of a return device device (anti-repression) and a pressure regulator (pressure reducer), which reduces the water pressure and stops to avoid the limits.
There are five basic types of water intrusion in a system of prevention
Drinking water in the drinking water system (if there is a link between them):
- A bag / air space (physical separation between networks - its size must
20-100 mm above the water);
- A two-pronged purpose;
- A series based on the principle of low pressure delivery
(Composed of two independent valves, a valve pressure differential and the reduction of the sample);
- A device for vacuum (consisting of a valve and a valve, the access of air, which can be executed independently of one another) break
- A device to break the vacuum atmosphere.
All this must be mounted horizontally. It also shows that the highest points of the column was mounted on the ground floor and the floor vent and relief valve fitted.